Description
Control includes safety shut-off, manual valve, two automatic operators, pressure regulator and pilot adjustment
Compact size
Provides two automatic valves
Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends
Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted
Meets codes requiring dual safety shut-off
Natural to LP and LP to natural conversion kits available for standard and slow opening gas valves
All adjustments, wiring connections and pilot outlet are accessible from top of control
Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure
Compatible with ECO connector
LITE-RITE (OFF-PILOT-ON) lighting sequence
Combination gas control for use in 24 VAC gas fired, standing pilot appliances with capacities from 30 - 300 cu-ft/hr
60-22513-03 LPG spring kit and 60-23430-01 natural gas spring kit included
Compact size
Provides two automatic valves
Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends
Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted
Meets codes requiring dual safety shut-off
Natural to LP and LP to natural conversion kits available for standard and slow opening gas valves
All adjustments, wiring connections and pilot outlet are accessible from top of control
Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure
Compatible with ECO connector
LITE-RITE (OFF-PILOT-ON) lighting sequence
Combination gas control for use in 24 VAC gas fired, standing pilot appliances with capacities from 30 - 300 cu-ft/hr
60-22513-03 LPG spring kit and 60-23430-01 natural gas spring kit included